Specifications:
Load Capacity: 100 000 lbs Single Line Tension
Overload: 150 % of Capacity
Operating Temperature Range: -40ºC to + 57ºC
Output: 2.5 mV/V; 0 - 5 VDC; 4 - 20 mA (two wire); 4 - 20 mA (three
wire)
Stipulations:
Accuracy: 1% of the full scale
Standard weight: 27 lbs
Overall length: 20"
Operation:
The EDLC is mainly used in drilling and service industry as a hook
load sensor. Variety of different output signals allows it to be used
with almost any instrumentation or control system. The EDLC is very
accurate and reliable device built to handle rough, drilling rig environment.